Sale 1
Sale 2
Sale 3

Dealer

WEB LINK

Bộ Ghi Dữ Liệu - Recorder model PHF, EDS10-77d

Hãng sản xuất :
Warranty :
Mode : PHF, EDS10-77d
Code : GE2-01859
Price : Call
Category : Other Instrumentation, Equipments
:
:
Views : 2899
Date update : 20/11/2011
Quantity :     
 
Description

Bộ Ghi Dữ Liệu - Recorder model PHF, EDS10-77d

Model : PHF, EDS10-77d
Manufacturer : FUJI ELECTRIC
Origin : JAPAN

 

 

 

Input system

Number of  input  points:
                            3  points    or    6    points     (Can    be    selected    at     the    time    of    purchase)
Input circuit:     Input    mutual    isolation
                            Resistance    bulb    measured    current: about    1    mA
Measuring cycles:
                              3    or    6    points….100ms    cycles
Recording cycle:    1    sec    to    12    hours

Input types:     Thermocouple,    resistance    bulb,    DC    voltage,    and    DC    current    (Shunt    resistors    are   fitted    in    input    terminals).
                           Note)    Order      a     shunt     resistor     (type:    PHZP0101)    separately.
Measuring range

Selection    of    input    types:
     By    key    operation    on    the    front    panel.    Note   
that    the    same    input    type    (thermocouple,   
resistance     bulb,     voltage)     should     be     se-
lected    for    channel    4    and    5.    Refer    to    ”Set-
ting    method    of    input    types”    for    details.

Burn-out    function:
Equipped    in    thermocouple    and    resistance   
bulb    inputs    as    standard,    and    overswings   
the    recording    to    100%    side.
Thermocouple    burn-out    current:   
approx.    0.2    µA

Input    filter    function:
Settable    for    each    channel     (primary    delay   
filter)        Time    constants    are    settable    in    the   
range    from    0    to    900    sec.

Scaling    function:
     Possible    by    DC    voltage    (current)    input
Scaling    range:    -32767    to    32767
Decimal    position:     settable    at    any    point
Unit    symbol:     settable    up    to    7    digits    and   
125+12    types

Subtraction    function:
     Subtraction    between    each    channel     is    al-
lowed.

Square    rooter    function:
     Square    rooter    can    be    performed    against   
the    input    value    per    each    channel.

Indication system

Indicator:     5.7”    STN    color    LCD    (320    x    240    dots)
with    backlight
     Note)    The    LCD    may    have    some    pixels    that    do    not    stay    on    or    off.
                   Due    to    the    characteristics    of    liquid    crystal,    the   
brightness    may    not    be    uniform,    which    is    not    a   
failure.

Color    of    indication:
14    colors

Applicable    language:
English,    French,    German,    Italian    (switch-
able)

Life    of    backlight:    50,000    hours    (20°C)
                                        (the     complete     indicator     unit     should     be    replaced    when    replacing    backlight).

Trend    display:     
Direction:    vertical    and    horizontal

Number    of    channels:    6    channels    or    4    chan-
nels    or    3    channels    for    the    screen    (Input:   
6    points    at    the    maximum).

Display    refreshment    cycles:
select    from    1    second    to    12    hours
No    numerical    value    display.    Scale    display/
no-display    can    be    selected.

Bar    graph    display:

Direction:    vertical

Number    of    channels:    6    channels    or    4    chan-
nels    or    3    channels    for    the    screen    (Input:   
6    points    at    the    maximum).

Display    refreshment    cycles:    1    second.
Digital    display:     Number    of    channels:    6    channels    or    4    chan-
nels    or    for    the    screen    (Input:    6    points    at   
the    maximum).

Display    refreshment    cycles:    1    second.

Event    summary    display:
Alarm    summary    and    message    summary   
can    be    displayed.   

Ethernet    log    display:
E-mail    sending,    FTP    server    log    in/off    and   
MODBUS    TCP/IP     communication     start/
stop    can    be    displayed.

Parameter    display/set:
Already-set    Data    Display    and    Set    Change   
Display    screen

TAG    indication:     Number.    of    characters    to    be    displayed:   
Up    to    8    characters    at    6    channels    on    one   
screen    or    up    to    16    (=    8    ×    2)    characters   
at    4    channels    on    one    screen.

Characters    to    be    displayed:
Alphanumerical    characters
Tag,    unit    and    channel    number    display:
It    depends    on    the    screen.        See    below   
table.

Data    save    cycles:
Linked    to    the    display    refreshment    cycles    on    the    “Trend    display”    screen.        However,    they     are     automatically     set     to     about     1    minute    if   the    refreshment    cycles    are    set    to    less    than    1    minute.

Trend    data:     Average,    instance    or    min.    and    max.    measured    values    out    of    measured    data     that    are    sampled    at    the    measuring    cycles   are    saved.

Event    data:     Saves     alarm     data     and     power    ON     data    when    the    power    turns    off    and    on    during    recording.

Storage    capacity    :

Approximately    4    years    when    the    display   
refresh    cycle    is    30    seconds    (in    the    case    of   
6-channel    recording    in    ASCII    data    format,   
and    512MB    Compact    Flash    is    used).    Refer   
to    Table    1.

Memory    usage:     Indicates    the    memory    which    has    already    used    on    the    screen.    When    all    the    memory    is     used     up,     you     can     stop    recording     or    delete     the     oldest     recording     file     to     save    the    newest    data.

Compact    flash    card    form:    PHZP1301-512
(CF    card)     (If     a     card    other     than     the     above     is    used,    no    operation    assurance    is    ensured. Meanwhile,     as     for     other     CF     cards     for   
which     operation     check    will     have     been    completed,    the    results    will    be    posted    on    our     company's     homepage     sequentially.   
Please    refer    to    this    website.) Recommended    PC    card    adaptor:  SanDisk    Corp.        SDAD-38   

Data    format:     Either     of    ASCII     or     binary     format     can     be    selected.     (Switching    cannot    be    made    while    the    recording    is    in    progress.    In    the    case    of    ASCII    format,    the    data    can    be    directly    read    on    Excel,    etc.)

Note:    The    data    recorded    in    binary    format    cannot    be    read    directly.
     Approximately    118    bytes    per    sample    (for    6-channel     input     in    ASCII     format)     or     approximately    28    bytes    (for    6-channel    input    in    binary   format)

Historical    trend    display:
The    past    data    can    be    displayed    from    the    Compact    Flash    or     internal    memory.    The    past    data    file    can    be     read    and    displayed    with   scroll     display     function     or     jump     the    cursor    to    the    position    which    you    entered    date     and     time.     Scale     display/no-display    can    be  selected.

Number    of    screen    groups:
     1     group     (Up     to     6     channels     per     1     group    can    be    registered.)

Keyboard
No.    of    Keys:     8

Function:     Use     to     select     various     screens     and     set   
various    parameters.

Recording function
xternal    memory    media:
Compact    Flash    card
(Format     as     FAT32,     FAT16     or     FAT,     or     recorder    can’t    read    and    write.)

Recording    capacity:
2GB    maximum    (compact    flash).        Limiting    the     recording     file     to     64MB     is     recom-mended     (for    112    hours     if    display    refresh   
cycle    is    1    second.        See    Table    1    (p.    6).)        (When    the    size    of    the    recording    file    comes    to    be    256MB    or    more,    a    new    file    is    created    automatically    and    recording    is    maintained.)
*    Please    change    the    compact    flash    every    six    month    to    prevent    the    data    losing.

Recording    method:
Turning    ON    the    REC    key    allows    measured    data    to    be    written    at    fixed    cycles.   
Recorded     as     a     new     file    whenever     the    recording    starts

Power supply
Rated    power    voltage: 100    to    240V    AC
Range    of    operating    voltage: 90    to    264V    AC
Supply    frequency: 50/60Hz    (both    employable)
Power    consumption

100V AC About 32VA
240V AC About 42VA

 

 

Structure
Mounting    method:

Panel-mounted    (vertical    panel)

Thickness    of    panel:
2    to    26    mm
Materials:     PC-ABS    for    case    and    bezel
Color:     Black
External    dimensions:
Panel-mounted:    160    (W)    ×    144    (H)    ×    185   
(D)    mm
Mass:     Approx.    1.5    kg    (no    option)
External    terminal    board:
Screw    terminals    (M3    thread)
RJ45    :    Ethernet    terminal    (option)

------------------------------------------------------------------------------------------------------------------------------------

ĐẠI LÝ PHÂN PHỐI CHÍNH THỨC TẠI VIỆT NAM CÔNG TY TNHH TM-DV-KT CAO VIỆT CƯỜNG
  Số 89 hẻm 249 Tân Kỳ Tân Quý, P.Tân Sơn Nhì, Q.Tân Phú, HCMC
Tel: 08-3813 4681/Fax: 08-3813 4680
Hotline: 0908 507 021/ 0909 951 237
| Email: sales@caovietcuong.com
Website: www.caovietcuong.com
| www.thietbidomuc.com