Sale 1
Sale 2
Sale 3

Dealer

WEB LINK

Bộ Ghi Dữ Liệu - Recorder model PHR-4, EDS10-74i

Hãng sản xuất :
Warranty :
Mode : PHR-4, EDS10-74i
Code : GE2-01861
Price : Call
Category : Other Instrumentation, Equipments
:
:
Views : 5392
Date update : 20/11/2011
Quantity :     
 
Description

Bộ Ghi Dữ Liệu - Recorder model PHR-4, EDS10-74i

Model : PHR-4, EDS10-74i
Manufacturer : FUJI ELECTRIC
Origin : JAPAN

 

 

 

Input system
Number of input points:9 points or 18 points (Can be selected at the time of purchase)
nput circuit:  Input    mutual     isolation     (See     "Others"     on    page    5    for    the    withstand    voltage)
Resistance    bulb    measured    current:
about.    1    mA
Measuring cycles: 9 or 18 points….100ms cycles
Recording cycle: 1    second    to    12    hours
nput types:  Thermocouple,    resistance    bulb,    DC    voltage,    and    DC    current    (Shunt    resistors    are    fitted    in    input    terminals).
Note)     Provide    a    shunt    resistor    (type:   
PHZP0101)    separately.
Measuring range

Note) B, R, S, K, E, J, T : JIS C 1602, DIN IEC 584-1
 N : NICOSIL-NISIL (IEC 584)
 W : 5%Re-26%Re · W (Hoskins Mfg. Co. USA)
 L : Fe-Cu · Ni (DIN 43710)
 U : Cu-Cu · Ni (DIN 43710)
 PN: Platinel
 JPt100 : JIS C 1604-1989 (Old JIS Pt 100)
 Pt100 : JIS C 1604, DIN IEC 751

Selection of input types:
     By     key     operation     on     the     front     panel .   
Note     that     the    same     input     type     (thermo-couple,     resistance    bulb,    voltage)    should    be     set     every     2     channels.    Refer     to     "Set-ting    method    of    input    types"    for    details.

Burn-out function:
Provided    as    standard    for    thermocouple   
and    resistance    bulb    inputs.        If    the    input   
has    been    open-circuited,    the    recording   
level    swings    over    100%.

Thermocouple    burn-out    current:   
approx.    0.2    µA
Input filter function:
Settable    for    each    channel    (primary    delay    filter) Time    constants    are    settable    in    the    range    from    0    to    900    sec.
Scaling function:  Possible    by    DC    voltage    (current)    input
Scaling    range:    -32767    to    32767
Decimal    position:
     settable    at    any    point
Unit    symbol:     Selectable    out    of    125    different    units    or    12    user    units    of    up    to    7    characters.
Subtraction function:
     Subtraction    between    each    channel     is    allowed.
Totalizing function:
     The    measured     value     of     each     channel    can     be     total ized.    Appl icable     to     dai ly,    monthly,     annual     or     external     input     totalizing.

F value calculation function:
     F     value     (extinction     value     of     bacteria     by    sterilization     by     heating)     can     be     calculated     from     the    measured     temperature    by    each    channel.   
     F     value     and    measured     temperature     can    be    displayed    and    recorded    using    2    channels.
Square rooter function:
     Square    rooter    can    be    performed    against    the    input    value    per    each    channel. Logarithmic calculation function:
     The    measured     value     of     each     channel    can    be    displayed    in    exponent    form.
Mathematics function:   
     The     fol lowing     calculation     is     avai lable   
with    the    math    function.
    1)    Computation    function
     Addition,     subtraction,    multipl ication,    division,     absolute     value,     exponential,    square-root     extraction,     LOG,     LN,     EXP,    humidity,    maximum,    minimum,    average,    and    integration.
    2)    Computation    input    enable
     Channel     input     (1     to     30    CH),    Total     input    (1     to    30    CH),    DI     (DI     to    DI10),    Communi-cation     input     (No.1     to    No.12),    Constant    (No.1    to    No.20).

Indication system

Indicator:  5.7"    TFT    color    LCD    (320    ×    240    dots)
with    backlight,    no    contrast    adjustment.
     On     the     LCD,     certain     picture     elements    remain     lit     or     extinguished.         On     account    of     the     nature     inherent     to     LCD,     the    brightness    may     be     non-uniform.         But,    such    are    not    troubles.

Color of indication:
14    colors
Applicable language:
English,    Japanese
Life of backlight: 50,000     hours     (20°C)     in     terms     of     total    lighting    time.
     (Replace     the     backlight     as     a     set     of     display    unit.        If    the    LCD    extinguishing    function    is    resorted    to,    the    LCD    can    be    used   
longer    as    much.)

Trend display:  Direction:    vertical    and    horizontal Number    of    channels:    10    or    4    channels    per    screen    group.        (select    from    up    to    30    channels).

Display    refreshment    cycles:
select    from    1    second    to    12    hours Scale    display    or    no-display    can    be    selected.

Bar graph display:
Number    of    channels:    10    or    4    channels    per    screen    group.        (select    from    up    to    30    channels).
Display    refreshment    cycles:    1    second.

Analog meter display:
     For     4     inputs     per     screen     group.          (input    from    1     to    4).    Display     in    bar    graphs    or     in    analog    meters    can    be    selected.
     Display    refresh    cycle:    1    second

Digital display:  Number     of     channels:     10     or     4     channels    per    screen    group.  (select    from    up    to    30    channels).

Display    refreshment    cycles:    1    second.

Totalizing data display:

Number    of    channels:    10    or    4    channels    per    screen    group.        (select    from    up    to    30    channels)

Display    refresh    cycle:    1    second.

Event summary display:
Alarm    summary    and    message    summary    can    be    displayed.    The    message    occurrence    information    and    message    display    can    be    switched.

Ethernet log display:
E-mail    sending,    FTP    server    log    in/off    and    MODBUS    TCP/IP    communication    start/stop    can    be    displayed.
Parameter display/set:
Already-set    Data    Display    and    Set   
Change    Display    screen

TAG indication:  Number    of    characters    to    be    displayed:   
Up    to    8    characters
Up     to     8     characters     (Note     1)    at    10-channel    display.
Up     to     16     characters     at      4    channel    display.

Note     1:    Up     to     7     characters    only     can    be    displayed    on    certain    screens.

Characters    to    be    displayed:
Alphanumerics,    hiraganas    and    katakanas. Tag,    unit    and    channel    No.    display:   
Which    can    be    displayed    depends    on    the    particular    screen.        Refer    to    the    table    below.(Keywords    only    are    extract-ed.)

Historical trend display:
Displays    past    recording    data    read    from    compact    flash,    currently    recording    data    or    just    recorded    data.        The    recording    chart    can    be    scrolled    or,    via    time    designation,    the    control    can    jump    to    an    arbitrary    recording    chart.

Number of screen groups:
     Four     groups     (Up     to     10     channels     per     1    group    can    be    registered.)

Keyboard
No. of Keys:  8
Function:  Use     to     select     various     screens     and     set   
various    parameters.

Recording function
External memory media:
Compact    Flash    card
Format    according    to    FAT32,    FAT16    or    FAT.        Otherwise,    reading    and    saving    are    impossible.

Recording capacity:
2GB    maximum    (compact    flash).        Limiting    the    recording    file    to    64    MB    is    recommended    (for    112    hours    if    display    refresh    cycle    is    1    second.        See    Table    1    (p. 7).)        (When    the    size    of    the    recording    file   
comes    to    be    256MB    or    more,    a    new    file    is    created    automatically    and    recording    is    maintained.)

*    Please    change    the    compact    flash    every    six    month    to    prevent    the    data    losing.

Recording method:
Turning    ON    the    REC    key    allows    measured    data    to    be    written    at    fixed    cycles.    Recorded    as    a    new    file    whenever    the    recording    starts.

Data save cycles: Linked    to    the    display    refreshment    cycles    on    the    ”Real    Time    Trend”    screen.         How-ever,    they    are    automatically    set    to    about   
1    minute     if     the     refreshment     cycles     are    set    to    less    than    1    minute.

Trend data:  Measurement     data     sampled     at    measurement     cycle     is     saved     in     terms     of    mean     value,     instantaneous     value     or    maximum/minimum    value.

Event data:  Saves    alarm    data    and    message    data. Further    saves    power    ON    and    OFF,    if    any,    after    starting    recording.

Totalizing value data:
Records    the    totalized    data    according    to    the    totalizing    type    selected    by    channels. Values    by    totalizing    types    or    total    from    the    beginning    of    totalizing,    whichever    selected,    can    be    recorded.        For    each    channel,    the    input    value    totalizing,    number    of    DI    inputs    or    measurement    at    times    when    DI    inputs    have    occurred    can    be    selected.        Input    values    to    be    totalized    are    selected    from    daily    report,    monthly    report,    yearly    report    and    external    input.

If    power    has    been    turned    off    and    on    while    totalizing,    the    totalizing    is   
resumed    at    last    value.        (Last    value    remains    saved,    but    data    during    power    OFF    is    not    totalized.)

Configuration data:
Configuration    data    can    be    saved.        And    this    data    can    also    download    to    recorder.

Storage capacity  :

Approximately    3    years    when    the    display    refresh    cycle    is    30    seconds    (in    case    of    9-channel    recording    in    ASCII    data    format,    and    512    MB    compact    flash    used). 
  
Refer    to    Table    1.

Residual capacity of memory:
Indicates    how    much    of    the    memory    card    has    been    used    on    the    screen.       
When    all    the    memory    is    used    up,    you    can    stop    recording    or    delete    the    oldest    recording    file    to    save    the    newest    data.

Compact flash card form: PHZP1301
(CF card)  (If     a     card    other     than     the     above     is    used,    no    operation    assurance    is    ensured.
Meanwhile,    as    for    other    CF    cards    for    which    operation    check    will    have    been    completed,    the    results    will    be    posted    on    our    company's    homepage    sequentially.    Please    refer    to    this    website.)

Data format:  Either     of    ASCII     or     binary     format     can     be    selected.     (Switching     cannot     be    made    while     the     recording     is     in     progress.     In    the     case     of    ASCII     format,     the     data     can    be    directly    read    on    Excel,    etc.)
     Note:    The     data     recorded     in     binary     format    cannot    be    read    directly.
     Approximately     166     bytes     per     sampling    for    maximum/minimum     recording     of    9-channel     input     in    ASCII     format,     or     approximately    40    bytes    for    maximum/minimum     recording     of     9-channel     input     in    binary    format.

Alarm function
No. of settings:  Up    to    4    alarms    for    each    channel    are    settable.
Type of alarm:  High/Low    limits
Indication:  Status    (alarm    types)    is    displayed    on    digital    display    unit    when    an    alarm    occurs.
Historical    display    on    alarm    summary    (Alarm    start/cancel    time    and    alarm    types)
Hysteresis:  Set    within     the     recording     range     of     0     to    100%
Acts    on    high    or    low    limit    alarm,    and   
does    not    affect    the    battery    alarm    nor    memory    full    alarm.
Relay output:  Number    of    points;    10    (option:    Cannot    be   
selected    if    the    number    of    input    points    is    18.)
Transistor output (open collector output): 18    points    (option)
Alarm latch function:
Holds    alarm    indication    and    alarm    output    even    after    measurement    value    has    left    the    alarm    range.
ON/OFF    operation    is    performed    accord-ing    to    key    setting.

------------------------------------------------------------------------------------------------------------------------------------

ĐẠI LÝ PHÂN PHỐI CHÍNH THỨC TẠI VIỆT NAM CÔNG TY TNHH TM-DV-KT CAO VIỆT CƯỜNG
  Số 89 hẻm 249 Tân Kỳ Tân Quý, P.Tân Sơn Nhì, Q.Tân Phú, HCMC
Tel: 08-3813 4681/Fax: 08-3813 4680
Hotline: 0908 507 021/ 0909 951 237
| Email: sales@caovietcuong.com
Website: www.caovietcuong.com
| www.thietbidomuc.com